Notifications
You must be signed in to change notification settings - Fork 69
Description
I used version ula_0.0.2 and also version ula_0.0.3 on 2 different genuine RP pico's (no clones).
With PulseView (nightly build, the last "stable" build 0.4.2 does not connect to the RP2040).
When pico is connected to a stable square wave generator signal of 100kHz, 3.3V high, 0V low, (GP15) withg good ground connection between generator and RP2040 I see 2 artefacts
1/ Sometimes data from channel 15 shows up on the channel 7 waveform in pulseview. This can very well be pulseview causing it.
2/ When I use sampling rate 1MHz, I see a nice square wave. When I use 10MHz the waveform is irregular (some pulses are not the correct pulse width). When I sample at 100Mhz the 100kHz square wave is not recognisable. In each pulse there are missing samples (low in stead of high).
Note, I am not using triggers, just RUN in pulseview.