Communication with the EasyM electricity meter occurs serially via two infrared data interfaces (DSS). The baud rate is 9600 Baud (8N1).
1274
+
All telegrams are encoded using the SML transport protocol (V1.04).
1275
+
1276
+
The electricity meter is a 3-Phase AC meter that can handle two tarifs as well as counters from the grid and what was delivered to the grid.
1277
+
When the PIN is entered more information is available on via the INFO-DSS like Voltage and Power per Phase.
1278
+
1279
+
1280
+
There are two communication interfaces:
1281
+
1282
+
* INFO-DSS: Unidirectional infrared interface. Permanently outputs (every second) billing-relevant measured values and other information. (used for the script)
1283
+
* MSB-DSS: Bidirectional infrared interface. Permanently outputs (every second) billing-relevant measured values and other information. Additionally, the MSB interface is used for setting meter parameters and controlling tariffs. (Not tested/ used for the script)
1284
+
1285
+
For the counter value precision 1 is used for the rest i only took the numbers without any decimal points
This script is for the EasyMeter Q1DB1004 variant of the Q1D series. This variant is a one-phase one-way electricity counter with a backstop mechanism.