OS-6997 bhyve should error check mutexes

This PR was migrated-from-gerrit, https://cr.joyent.us/#/c/4139/.
The raw archive of this CR is here.
See MANTA-4594 for info on Joyent Eng's migration from Gerrit.

CR discussion

@mgerdts commented at 2018-06-05T04:44:02

Patch Set 1: Code-Review-1

Quick untested hack

@mgerdts commented at 2018-06-05T12:48:25

Uploaded patch set 3: Commit message was updated.

@mgerdts commented at 2018-06-05T15:00:24

Patch Set 4: -Code-Review

I'm not sure if this is a great idea or not, but would like feedback.

When mutexes are initialized with the static initializers, flag.flag1 (lwp_mutex_t) or __pthread_mutex_flags.__pthread_mutex_flag1 (pthread_mutex_t) does not get set to (LOCK_INITED). This is the case with PTHREAD_MUTEX_INITIALIZER and PTHREAD_ERRORCHECK_MUTEX_INITIALIZER_NP. Aside from that, mdb shows PTHREAD_ERRORCHECK_MUTEX_INITIALIZER_NP and _check_mutex_init() leading to the same results.

To catch issues with future syncs, we may want to add an ASSERT3S() in _check_mutex_lock() to ensure that PTHREAD_MUTEX_ERRORCHECK is set.

@mgerdts commented at 2018-06-05T15:25:19

Patch Set 4:

Summary of comments at https://chat.joyent.us/joyent/pl/q1r4j3atwpr55cnjc4i6z155wy

  • No need to edit all the files, just use -include CFLAG
  • Use mutex_enter() and mutex_exit()
  • Use mutex_init(&mtx, LOCK_ERRORCHECK, NULL)
  • Consider adding a pthread version of mutex_*() to avoid casts